Radon grab sampling in water by means of radon transfer in activated charcoal collector

Galli, G. and Guadoni, C. and Mancini, C. (1999) Radon grab sampling in water by means of radon transfer in activated charcoal collector. Il nuovo cimento C, 22 C (3-4). pp. 583-588. ISSN 1826-9885

[img]
Preview
Text
ncc7982.pdf - Published Version

Download (1MB) | Preview
Official URL: https://www.sif.it/riviste/sif/ncc/econtents/1999/...

Abstract

The proposed portable device is suitable for radon surveys in water-bearing strata. It allows a complete tranfer in activated charcoal canisters of radon dissolved in water collected with a 0.6 l bottle. The detection is performed in laboratory with a low background g-ray spectrometer utilizing a 39339 NaI(Tl) scintillator only after about ten hours. This time is necessary to let radon be uniformly distributed within the activated charcoal.

Item Type: Article
Additional Information: Paper presented at the “Fourth International Conference on Rare Gas Geochemistry”, Rome, October 8-10, 1997.
Uncontrolled Keywords: Phenomena related to earthquake prediction; Earth tides; groundwater; conference proceedings