De Luca, S. and Acosta, L. and Auditore, L. and Boiano, C. and Cardella, G. (2016) Test of GET Electronics for the CHIMERA and FARCOS multi-detectors. Il nuovo cimento C, 39 (6). pp. 1-5. ISSN 1826-9885
|
Text
ncc11359.pdf - Published Version Download (273kB) | Preview |
Abstract
In this paper we present the results of the tests on the new digital electronics GET (General Electronics for Tpc), which will be used for the readout of the CsI(Tl) detectors of CHIMERA (Charged Heavy Ion Mass and Energy Resolving Array) and for the new correlator FARCOS (Femtoscope ARray for COrrelations and Spectroscopy). The new electronics allows us to digitize the full waveform of the signals produced by the detector. Among its features it is worth noticing the compactness and low power consumption (5W for 256 channels). Tests have been performed with pulsers, radioactive sources and ion beams. With such electronics very good results in energy resolution and isotope separation of the detected fragments were obtained, by using both hardware and software filters.
Item Type: | Article |
---|---|
Subjects: | 500 Scienze naturali e Matematica > 530 Fisica |
Depositing User: | Marina Spanti |
Date Deposited: | 16 Nov 2020 20:41 |
Last Modified: | 16 Nov 2020 20:41 |
URI: | http://eprints.bice.rm.cnr.it/id/eprint/19688 |
Actions (login required)
View Item |