Liverani, A. and Loffredo, F. and Fiore, F. and Correra, M. and La Verde, G. and Pugliese, M. (2018) Evaluation of the dose dependence on the eye lens from the position of the dosimeter for the operators exposed in interventional radiology. Il nuovo cimento C, 41 (6). pp. 1-5. ISSN 1826-9885
|
Text
ncc11681.pdf - Published Version Download (206kB) | Preview |
Abstract
The 2013/59 EURATOM Directive of the 5th of December lays down basic safety standards concerning protection against dangers arising from exposure to ionizing radiation. The Directive lowers the limit on equivalent doses to the eye lens from 150 mSv to 20 mSv per year, according to the publication 103 of ICRP. The aim of this work is to evaluate the current status of the eye lens radiation exposure in an Interventional Radiology Department depending on the position of the specific dosimeters used by exposed workers, to compare the measured doses with the limit imposed by the Directive. Methods: the equivalent dose was assessed, over a period of 30 days, using four specific Hp dosimeters (Ainsbury E. A. et al., Mutat. Res./Rev. Mutat. Res., 770, Part B (2016) 238), placed in four different points on a personal protective device. For each dosimeter we evaluated the equivalent dose absorbed and we compared these doses with the new limits of the 2013/59 EURATOM Directive.