Alemanno, F. (2024) Comparison of SiPMs and PMTs for calorimetry applications in the DUNE near detector complex. Il nuovo cimento C, 47 (5). pp. 1-4. ISSN 1826-9885
|
Text
ncc13087.pdf - Published Version Download (246kB) | Preview |
Abstract
The KLOE electromagnetic calorimeter, selected for reuse in the DUNE experiment, has been under investigation for the potential replacement of traditional Photomultiplier Tubes (PMTs) with Silicon Photomultipliers (SiPMs). In this study, a segment of the KLOE lead-scintillating fiber calorimeter was equipped with SiPM arrays on one side and conventional PMTs on the other side. The efficiency and timing resolution of SiPMs are evaluated and compared with KLOEPMTs. The findings contribute to determining the feasibility of substituting PMTs with SiPMs.
Item Type: | Article |
---|---|
Subjects: | 500 Scienze naturali e Matematica > 530 Fisica |
Depositing User: | Marina Spanti |
Date Deposited: | 10 Jan 2025 11:52 |