Satoh, S. (2015) Development of wide area detector for the 2012 model of the 6Li time analyzer neutron detector system. Il nuovo cimento C, 38 (6). pp. 1-4. ISSN 1826-9885
|
Text
ncc11091.pdf - Published Version Download (396kB) | Preview |
Abstract
A 2012 model 6Li time analyzer neutron detector (LiTA12) system has been developed as a high-count-rate neutron detector. An exclusive function with a center-of-gravity calculation, which not only prevents over-counting due to cross-talk, but also obtains a fine position resolution, has been included. As a highcount-rate detector, this device can detect neutrons with a 3mm position resolution in a detection area of 5×5 cm2 and is arranged as a 16×16 matrix with a detection efficiency of approximately 40% of that of a 3He detector. A maximum count rate of 50 million counts per second (Mcps) is obtained. Using the exclusive function, the center-of-gravity pixel size obtained is 0.4 mm, although the actual pixel size is 3mm. Furthermore, this function also enables a wide area detector in an area of 10 × 10 cm2 using four multi-anode (8 × 8 matrix) photomultiplier tubes. In this case, the pixel size is 0.8mm, although the actual pixel size is 6 mm.
Item Type: | Article |
---|---|
Subjects: | 500 Scienze naturali e Matematica > 530 Fisica |
Depositing User: | Marina Spanti |
Date Deposited: | 23 Jun 2020 10:02 |
Last Modified: | 23 Jun 2020 10:02 |
URI: | http://eprints.bice.rm.cnr.it/id/eprint/19187 |
Actions (login required)
View Item |