La Verde, G. and Fronzino, T. and La Commara, M. and D'Avino, V. and Pugliese, M. (2020) Electret ion chamber and environmental gamma radiation background: Preliminary results on the optimization of a radon gas measurement system. Il nuovo cimento C, 43 (6). pp. 1-6. ISSN 1826-9885
Text
ncc12137.pdf - Published Version Download (192kB) |
Abstract
A study to evaluate the feasibility of using a system routinely used for measurements of radon gas concentration for measuring the background of gamma radiation was carried out. This approach would reduce the employment of different detectors to a single type, standardizing the methodology adopted and reducing the costs affecting other types of detectors. A 1440 hours long measurement was performed, using an experimental EIC system. The results were compared with measurements provided by a proportional counter and thermoluminescence dosimeters used as a reference. The results suggest the potential of the EIC system for unconventional use for gamma radiation background measurements.