Design and performance of the Phase 2 CMS experiment electromagnetic calorimeter readout electronics

Basile, C. (2024) Design and performance of the Phase 2 CMS experiment electromagnetic calorimeter readout electronics. Il nuovo cimento C, 47 (3). pp. 1-5. ISSN 1826-9885

[img]
Preview
Text
ncc12953.pdf - Published Version

Download (206kB) | Preview
Official URL: https://www.sif.it/riviste/sif/ncc/econtents/2024/...

Abstract

The High Luminosity LHC project aims to increase the instanta- neous luminosity of the collisions by a factor of 4 compared to the value at which the LHC currently operates. To cope with these new data taking conditions, the central part of the CMS electromagnetic calorimeter will undergo a complete up- grade of both the on-detector electronics and the readout electronics located in the service cavern. Only the lead-tungstate crystals and the avalanche photodiodes are expected to maintain good performance and do not need to be replaced. The results of the 2018 and 2021 test beam campaigns are presented. Electron beams up to 250 GeV were employed to test the Phase 2 electronics mounted on the ECAL crystals in terms of time and energy resolution.

Item Type: Article
Subjects: 500 Scienze naturali e Matematica > 530 Fisica
Depositing User: Marina Spanti
Date Deposited: 10 Jul 2024 16:12
Last Modified: 10 Jul 2024 16:12
URI: http://eprints.bice.rm.cnr.it/id/eprint/22994

Actions (login required)

View Item View Item