Stress distribution on a three-unit implant-supported zirconia framework. A 3D finite element analysis and fatigue test

Sannino, Gianpaolo and Pozzi, A. and Schiavetti, R. and Barlattani, Alberto (2012) Stress distribution on a three-unit implant-supported zirconia framework. A 3D finite element analysis and fatigue test. Oral & implantology, 5 (1). pp. 11-20. ISSN 2035-2468

[img]
Preview
PDF
article(74).pdf - Published Version

Download (1MB)
Official URL: http://www.oimplantology.it/index.php?PAGE=articol...

Abstract

Purpose: The purpose of this study was to investigate, by finite element analysis (FEA) and fatigue analysis, the influence of different loading conditions on the stress distribution in a 3-unit implant-supported Y-TZP fixed partial denture (FPD). Material and methods: A three-dimensional FEM model was developed. The materials used in this study were assumed to be linearly elastic, homogeneous and isotropic. 100 N and 300 N loads over a 0,5 mm2 areas with different angles (0°, 15° and 35°) and locations were applied on the prosthesis and the distribution of equivalent von Mises stress was investigated. A fatigue analysis was carried out too. Results: maximum stresses were found at the connector region of the framework when the intermediate element is loaded (100 N load pattern: 32,9 MPa, 33 MPa and 51,8 MPa; 300 N load pattern: 98,6 MPa, 102,8 MPa and 155,7 MPa, respectively with 0°, 15° and 35° of inclination). Results confirmed the vulnerability of both connector areas even if just one pillar was loaded with an increase in stress when angle of load inclination is larger. The cyclic fatigue evaluation indicates a strong propensity for fatigue behavior, presenting a considerable range of loading conditions. No fracture fatigue occurred with a 100 N force. A 300 N force applied to the pontic produces no fatigue problems because the load is equally shared by whole system. A 300 N force applied to one of the two pillars, or to both implants generates fatigue problems. Conclusion: F.E.M. analysis of a 3-unit implant-supported Y-TZPFPD, give accurate information about loading conditions for clinical success over time. Fatigue analysis results show structural reliability of the Y-TZP as framework material for 3-unit posterior FPDs.

Item Type: Article
Uncontrolled Keywords: Finite element analysis, zirconia framework, fatigue analysis
Subjects: 600 Tecnologia - Scienze applicate > 610 Medicina e salute (Classificare qui la tecnologia dei servizi medici) > 617 Rami vari della medicina; Chirurgia > 617.6 Odontoiatria
Depositing User: Nadia Del Gobbo
Date Deposited: 16 Apr 2013 09:55
Last Modified: 16 May 2013 10:34
URI: http://eprints.bice.rm.cnr.it/id/eprint/4947

Actions (login required)

View Item View Item